Welcome to the InspectionNews - Home Inspection forums.
You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

04-18-2008, 04:20 AM
|
|
Member
|
|
Join Date: Dec 2007
Location: Vero Beach Florida
Posts: 211
|
|
|
drain venting
2005 house; the pool and spa had pipes that appeared to be vent pipes for the drains, but htey were capped off. Both the pool and spa had two drain locations with anti vortex covers. Am i missing something? these vents are not needed? or ?
|
|

04-18-2008, 07:54 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Longwood, FL
Posts: 307
|
|
|
Re: drain venting
If (because I can't see the rest of the piping & equipment) those pipes are part of the Suction Limiting Vent System, they need to be open to the atmosphere with tamper resistant covers. If a high vacuum event occurs, the air from the vents breaks the suction.
Dom.
|
|

04-18-2008, 08:46 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,728
|
|
|
Re: drain venting
Typically I see two 90 degree elbows installed on top of those, leaving the opening down-turned.
As Dom said, they need to be open.
|
|

04-20-2008, 06:06 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Chandler, AZ
Posts: 40
|
|
|
Re: drain venting
Could this be for future plumbing? I didn't see where the pipes were connected to the pool equipment. I've seen this when folks plan a fountain, or other water feature.
Just came to mind when I saw the pics.
Take it easy
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Plumbing/venting |
Richard Roshak |
Plumbing System: Home Inspection and Commercial Inspection |
4 |
04-12-2008 07:19 PM |
| HE Flue Venting |
Jim Robinson |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
1 |
02-18-2008 08:26 PM |
| h2o venting |
cris donato |
Plumbing System: Home Inspection and Commercial Inspection |
4 |
01-10-2008 12:41 PM |
| Venting Issues |
Michael Thomas |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
6 |
11-18-2007 01:50 PM |
| Venting for gas fireplace |
Jon mackay |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
3 |
06-19-2007 06:01 AM |
All times are GMT -7. The time now is 11:17 PM.
| | |
|

All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by
RedTyger