    Default Roof to wall flashing/counter flashing ?

    Hello to all from a new poster who needs information.

    Have new construction with roof to wall intersection. Step flashing installed with hardboard siding used as counter flashing. Shingles are touching siding. I believe there should be gap of 1 1/2" to 2" between shingles and siding to prevent wicking.

    If correct, could someone direct me to a "source" to document the gap requirement.

    My first thought was code, but couldn't find gap requirement in 2006 IRC for roof to wall flashing.

    Thanks in advance for comments/suggestions.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Member Benefits1

  2. #2
    Join Date
    Mar 2008
    Location
    Charlotte NC
    Posts
    2,304

    Default Re: Roof to wall flashing/counter flashing ?

    Quote Originally Posted by Bill Williamson View Post
    Hello to all from a new poster who needs information.

    Have new construction with roof to wall intersection. Step flashing installed with hardboard siding used as counter flashing. Shingles are touching siding. I believe there should be gap of 1 1/2" to 2" between shingles and siding to prevent wicking.

    If correct, could someone direct me to a "source" to document the gap requirement.

    My first thought was code, but couldn't find gap requirement in 2006 IRC for roof to wall flashing.

    Thanks in advance for comments/suggestions.
    Welcome aboard Bill.

    The subject has been beat to death several times on this forum. You should be able to find it with a search.

    If you would rather, you can Google Hardie siding (that's what I think you have?). Hardie has installation instructions that are for different areas of the country. I think 2" is what Hardie wants as a space from shingles, but you will need to verify by location.

    The beatings will continue until morale has improved. mgt.

  3. #3
    chris mcintyre's Avatar
    chris mcintyre Guest

    Default Re: Roof to wall flashing/counter flashing ?

    If it is Hardi siding you are in hz10 and the requirement is 1" to 2", there is also a kick out flashing required at the bottom.

    http://www.jameshardie.com/pdf/insta...plank-hz10.pdf

    Trim looks like Miratec to me and it is required to be 1" from the shingles.

    http://www.miratectrim.com/pdf/Installation.pdf

    The manufactures installation instructions, in essence, are the code. So once you are sure who makes the product.....


  4. #4
    Bill Williamson's Avatar
    Bill Williamson Guest

    Default Re: Roof to wall flashing/counter flashing ?

    Thanks for the response. I appreciate it.

    Vern, before posting I did a search and reviewed several post. They didn't, however, seem to answer my question.

    Chris, thanks, will use mfg's installation instructions as source.


  5. #5
    Join Date
    Dec 2008
    Location
    Mesa, Arizona
    Posts
    45

    Default Re: Roof to wall flashing/counter flashing ?

    In the second picture the step flashing is on decking. Was the underlayment placed under the flashing ( before shingles installed) and if so how was it secured ?

    Jeff Moore AZ Cert#49250
    Level II Thermographer
    http:www.quantumhomeinspections.com

  6. #6
    Bill Williamson's Avatar
    Bill Williamson Guest

    Default Re: Roof to wall flashing/counter flashing ?

    Jeff,

    Unable to answer your question. The second pic is actually the first one taken. Went back the second day after pic taken and roofing had been installed (the first pic).

    Underlayment was visible at eave and under flashing. It appears roofer slid the underlayment under the flashing but can't tell how fastened.

    I just started doing new construction inspections with this builder and have a few little kinks we will need to work out with him


  7. #7

    Default Re: Roof to wall flashing/counter flashing ?

    Is it common practice for the siding to be installed before the roof covering in some areas of the country?


  8. #8
    Join Date
    Mar 2007
    Location
    Lake Barrington, IL
    Posts
    1,367

    Default Re: Roof to wall flashing/counter flashing ?

    I'll also chime in on the absent kick out flashing that Chris mentioned. If not present, it's a point of water entry.

    Eric Barker, ACI
    Lake Barrington, IL

  9. #9
    Join Date
    Jan 2011
    Location
    Parkersburg, WV
    Posts
    9

    Default Re: Roof to wall flashing/counter flashing ?

    No kickouts, no soffit vent, no gap between shingles and siding, no counterflashing (maybe not required, but should be. At least use a piece of removeable siding so it can be removed for reroofing), no visible ridge vent or roof drip edge.

    Did they use a good roof underlayment? How about foundation waterproofing and french drains?

    I would also check for pan flashing under windows and doors, head flashing integrated with house wrap, proper deck flashing with end dams and chimney cap, crickets, step flashing and kickouts.

    Looks like typical construction- by most contractors. You have more than a few kinks bo work out. Good luck!

    Mike Minigh
    MoistureTech
    304-904-6055