InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 08-03-2007, 10:46 AM
imported_John Smith imported_John Smith is offline
Member
 
Join Date: Mar 2007
Location: Alvin Texas
Posts: 483
Direct TV Installers - Another Quality Job
A recent observation on a home in Houston. Owner reported they just had Direct TV installed a month ago.

I wonder if this guy could get them to fix it. This is something that appears to have been intentional. I dont know how else you could explain it. Surely they arent that stupid.
Attached Images
File Type: jpg IM000557.jpg (96.9 KB, 100 views)
File Type: jpg IM000558.jpg (84.6 KB, 94 views)
Reply With Quote
IC Home Inspection Report Writing
  #2 (permalink)  
Old 08-03-2007, 12:02 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 777
Re: Direct TV Installers - Another Quality Job
It's hard to tell what it is that you are pointing out, imp_John. Is that a bolt or a screw through the co-ax cable? Or are you pointing out the damage to the roof caused by mounting the tripod to the roof?
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #3 (permalink)  
Old 08-03-2007, 04:56 PM
Joe Nernberg's Avatar
Joe Nernberg Joe Nernberg is offline
Member
 
Join Date: Mar 2007
Location: Agoura Hills, CA
Posts: 99
Re: Direct TV Installers - Another Quality Job
In my experience, 90% of these installers do not ground the satellite dish. Many thanks to Mike Holt for education and visuals.
Attached Images
File Type: jpg SatelliteDishGrounding.jpg (62.4 KB, 39 views)
Reply With Quote
  #4 (permalink)  
Old 08-03-2007, 05:02 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,632
Re: Direct TV Installers - Another Quality Job
Looks like they lost some granules on those shingles with the installation of the dish.
__________________
This space is now available for sale or for lease. Contact your broker if interested. Serious inquiries only.
Reply With Quote
  #5 (permalink)  
Old 08-03-2007, 07:02 PM
imported_John Smith imported_John Smith is offline
Member
 
Join Date: Mar 2007
Location: Alvin Texas
Posts: 483
Re: Direct TV Installers - Another Quality Job
Sorry guys. I thought it was evident in the photo. They drilled a hole in the roof and didnt put anything in it, or over it. I dont see how it could have been a mistake in mounting the dish bracket. They are about 6" away from the bracket. The hole is probably 3/8" dia. Look closely at the 1st photo (showing bracket for reference) then look at the 2nd photo (illustrating the hole).


You would think they could at least put some sealant or a screw and sealant.
Reply With Quote
  #6 (permalink)  
Old 08-03-2007, 08:26 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 777
Re: Direct TV Installers - Another Quality Job
Quote:
Originally Posted by imported_John Smith View Post
You would think they could at least put some sealant or a screw and sealant.
Are you kidding? Around here ROOFERS don't caulk the nail holes when they pull their toe boards. They don't even respect their own work. Why should anybody else?
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #7 (permalink)  
Old 08-04-2007, 06:29 PM
Nolan Kienitz's Avatar
Nolan Kienitz Nolan Kienitz is offline
Member
 
Join Date: Mar 2007
Location: Dallas Home Inspections
Posts: 433
Re: Direct TV Installers - Another Quality Job
John,

You saw it, you have the images ... I'm sure you put 'em in the report with a red circle around the hole and base mounting points for the tripod ... all need to be sealed and caulked to minimize water intrusion to roof deck and attic space and beyond.

Good shots.
__________________
Cheers - Nolan E. Kienitz, HCRI
Dallas Home Inspector
www.NolansInspections.com
Reply With Quote
  #8 (permalink)  
Old 08-05-2007, 12:48 PM
imported_John Smith imported_John Smith is offline
Member
 
Join Date: Mar 2007
Location: Alvin Texas
Posts: 483
Re: Direct TV Installers - Another Quality Job
Do you think it would be better to go ahead and install a wood screw into the hole and then siliconeroofing sealant/ over it?

Seems like a belt and suspenders approach, but I think it would be better than just trying to seal over it.
Reply With Quote
  #9 (permalink)  
Old 08-05-2007, 12:54 PM
Rick Cantrell Rick Cantrell is offline
Member
 
Join Date: Mar 2007
Location: Columbus GA
Posts: 751
Re: Direct TV Installers - Another Quality Job
imported_John SmithDo you think it would be better to go ahead and install a wood screw into the hole and then siliconeroofing sealant/ over it?

Seems like a belt and suspenders approach, but I think it would be better than just trying to seal over it.

No. Lift shingle tap, slide in a piece of galv. tin over the hole, apply sealant on top of tin, press tab into sealant.
__________________
Rick Cantrell
Columbus GA
Reply With Quote
IC Home Inspection Report Writing
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Direct Marketing Bob R Business Operations: Home Inspectors & Commercial Inspectors 6 06-13-2007 07:04 AM
Gray PVC for direct vent furnace Jon mackay Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 0 06-08-2007 05:52 AM
LP tank near direct vent Frank Bombardiere Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 1 05-22-2007 07:11 PM
StructuredRisk Named Recipient of RIMS 2007 Arthur Quern Quality Award - Earthtimes.o Brian Hannigan Expert Witness and Defect Litigation: Home Inspection & Commercial Inspection 0 05-17-2007 05:30 PM
Quality of work Eric Van De Ven Electrical Systems: Home Inspection and Commercial Inspection 2 04-04-2007 07:26 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 11:39 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger