You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 09-27-2007, 11:25 AM
David Banks David Banks is offline
Member
 
Join Date: Mar 2007
Location: Southborough, MA
Posts: 917
Roof sidewall intersection
Is this venting for bump out of room? Looks like venting material similar to ridge vent. It is lifting off roof with loose nails. Looks like they tried same thing on unheated three season porch also. Not needed there correct. They then covered with shingles. This has caused shingles to bend and crack.
Attached Images
File Type: jpg porchsbumproom.jpg (30.8 KB, 61 views)
File Type: jpg Roof.jpg (46.9 KB, 80 views)
File Type: jpg Roof1.jpg (57.6 KB, 67 views)
File Type: jpg Roof2.jpg (53.9 KB, 80 views)
__________________
Dave
Reply With Quote
Home inspection
  #2 (permalink)  
Old 09-27-2007, 02:31 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 672
Re: Roof sidewall intersection
Looks like improper use of a ridge vent to me. I would defer to a roofer.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #3 (permalink)  
Old 09-27-2007, 02:41 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is online now
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,676
Re: Roof sidewall intersection
That is a ridge vent not a slope vent! Yep, I betting that the manufacturer has not thought about it being used for that.
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #4 (permalink)  
Old 09-27-2007, 02:56 PM
Jim Robinson's Avatar
Jim Robinson Jim Robinson is offline
Member
 
Join Date: Mar 2007
Location: New Mexico
Posts: 314
Re: Roof sidewall intersection
Coravent has a product for that application.

Cor-A-Vent : Roof-to-Wall Ventilation

I can't tell if that is what they used, but it doesn't look like it is to me. I don't know what's going on in the other pictures, but it doesn't look right.
__________________
Jim Robinson
New Mexico, USA
Reply With Quote
  #5 (permalink)  
Old 09-27-2007, 04:40 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is online now
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,676
Re: Roof sidewall intersection
Quote:
Originally Posted by Jim Robinson View Post
Coravent has a product for that application.

Cor-A-Vent : Roof-to-Wall Ventilation

I can't tell if that is what they used, but it doesn't look like it is to me. I don't know what's going on in the other pictures, but it doesn't look right.
I thought about the Coravent product, my house has it. But looking at that picture it looks like they have cut a ridge vent. With the Coravent Roof to Wall vent, you leave the front edge open just like a ridge vent. In the picture they have shingled over it. Regardless of what it is, it is wrong. What do others think??
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com

Last edited by Scott Patterson : 09-27-2007 at 04:45 PM.
Reply With Quote
  #6 (permalink)  
Old 09-27-2007, 07:59 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,035
Re: Roof sidewall intersection
Scott,

Looked like a ridge vent to me too.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
  #7 (permalink)  
Old 09-27-2007, 08:31 PM
David Banks David Banks is offline
Member
 
Join Date: Mar 2007
Location: Southborough, MA
Posts: 917
Re: Roof sidewall intersection
Quote:
Originally Posted by Scott Patterson View Post
I thought about the Coravent product, my house has it. But looking at that picture it looks like they have cut a ridge vent. With the Coravent Roof to Wall vent, you leave the front edge open just like a ridge vent. In the picture they have shingled over it. Regardless of what it is, it is wrong. What do others think??
I agree Scott. They may have shingled over it because it is a non heated porch. But that begs the question why is it there in the first place.
Potential for future heated 4 season room? Na people do not think that far ahead.
The other pic with exposed vent should have a cap or shingles according to Coravent. Poor shape and loose and lifting off roof but no leaks inside. Go figure.
Thanks all for your input.
__________________
Dave
Reply With Quote
  #8 (permalink)  
Old 09-28-2007, 04:53 AM
Mike Gault's Avatar
Mike Gault Mike Gault is offline
Member
 
Join Date: Mar 2007
Posts: 8
Re: Roof sidewall intersection
Looks like half a ridge vent at that... defer to a licensed roofer.
Reply With Quote
  #9 (permalink)  
Old 09-29-2007, 06:25 AM
Jimmy Bacco Jimmy Bacco is offline
Member
 
Join Date: Aug 2007
Location: Indiana
Posts: 11
Re: Roof sidewall intersection
[quote=Mike Gault;19913]Looks like half a ridge vent at that... [quote]

...well, it is only half a ridge!
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rafter intersection Jeff Eastman Attic Areas: Home Inspection and Commercial Inspection 4 06-23-2007 08:15 AM


All times are GMT -7. The time now is 03:47 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger