Registration is FREE!... and will get rid of this top message
Welcome to InspectionNews.net.
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.
There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.
Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!
Registration is FREE, fast and easy so please, join InspectionNews today!
Why join InspectionNews? Read the Testimonials
Looking for Education? We recommend Casey, O'Malley and Associates

If you have any problems with the registration process or your account login, please contact us.
|
|

03-05-2008, 12:43 PM
|
 |
Member
|
|
Join Date: Sep 2007
Location: Fredericksburg, VA
Posts: 185
|
|
|
Drip Edge Variant
Last summer there was a discussion thread on the merits of drip edge flashing. I am seeing locally a lot of DYI type of flashing incuded in aluminum fascia wrapping. The aluminum wrap is started behind the fascia, wrapped under, up, and started and taken back over the top. BUT, instead of doing a standard finish on the wrap, the aluminum is bent back at an acute angle to meet the bottom of the shingle overhang. There is no other drip edge flashing. I personally don't see where this would do the same job of as a good HD preformed flashing as intended by the shingle manufaturers and IRC 2006.
The picture shows the wrap job from the front. The gutter had not been installed when this construction inspection was made. Comments?
__________________
The above statements are expressed solely as my opinion and in all probability will conflict with someone else's.
Stu www.VaInspectionService.com
|
|

03-05-2008, 04:31 PM
|
|
Member
|
|
Join Date: Feb 2008
Location: Caledon, Ontario
Posts: 1,131
|
|
|
Re: Drip Edge Variant
Cutting corners so to speak.
I would prefer galvanized drip edge, myself.
__________________
The value of experience is not in seeing much, but in seeing wisely. - Sir William Osler 1905
|
|

03-05-2008, 05:49 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Connecticut
Posts: 1,147
|
|
|
Re: Drip Edge Variant
Depends how you look at it. A Drip edge is not designed to create the Drip but to hold the shingle out away from the facia without drooping. Preferably to be used with a gutter.
But the overlap of the shingles on the top of the nailed section of the drip edge also adds drainage integrity.
|
|

03-05-2008, 05:53 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
|
|
|
Re: Drip Edge Variant
Stuart,
What you described is a 'water trap specially designed to rot fascias out'. 
|
|

03-05-2008, 06:44 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Allen, Texas
Posts: 2,497
|
|
|
Re: Drip Edge Variant
My thoughts exactly, Jerry.
|
|

03-05-2008, 09:48 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,097
|
|
|
Re: Drip Edge Variant
Agreed.
Not only will it eventually cause rot, the way the corner-returns are cut, this will cause the lower course to lift.
RR
__________________
"If con is the opposite of pro, is Congress the opposite of progress?"
Richard Rushing, HCRI
Duncanville, Tx.
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Drip Legs |
John Thompson |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
18 |
01-21-2008 01:50 PM |
| Purpose of the Drip Loop at SE |
Don Emerson |
Electrical Systems: Home Inspection and Commercial Inspection |
11 |
11-08-2007 08:08 PM |
| Recessed wall from edge of foundation |
Jeff Eastman |
Building Envelope: Home Inspection and Commercial Inspection |
7 |
11-07-2007 11:48 PM |
| Gas Drip. |
David Banks |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
6 |
09-24-2007 09:45 AM |
| Purpose of metal drip edge |
Jeff Eastman |
Roofing System: Home Inspection and Commercial Inspection |
43 |
07-02-2007 05:49 PM |
All times are GMT -7. The time now is 04:45 PM.
| | |
|