You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 03-16-2008, 07:39 AM
Reis Pearson Reis Pearson is offline
Member
 
Join Date: Jan 2008
Location: Seattle
Posts: 64
Flashing
I've run into this a couple of times and have been referring to it as improperly installed drip edge and wanted to get some feedback from the forum. I see major flaws in this design and wanted to know if this is a common practice or I just have the pleasure of running across the same roofer who hasn't had any problems with it??
Attached Images
File Type: jpg Photos 022.jpg (26.9 KB, 49 views)
Reply With Quote
  #2 (permalink)  
Old 03-16-2008, 09:32 AM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is online now
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,747
Re: Flashing
Yes it is wrong. The metal drip edge goes under the shingles.
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #3 (permalink)  
Old 03-16-2008, 09:42 AM
Nick Ostrowski Nick Ostrowski is offline
Member
 
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 759
Re: Flashing
Reis, that method of installation is common...........amongst people who don't know what they're doing.
Reply With Quote
  #4 (permalink)  
Old 03-16-2008, 10:25 AM
Brandon Chew Brandon Chew is offline
Member
 
Join Date: Mar 2007
Location: Albany, NY
Posts: 284
Re: Flashing
There was probably an inspection done prior to yours and the inspector wrote up the lack of drip edge, so they "fixed" it.

Looks like a good way to rot out the fascia and roof decking. You don't get any rain in Seattle, do you?

What Nick said...
Reply With Quote
  #5 (permalink)  
Old 03-16-2008, 11:07 AM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,148
Re: Flashing
http://www.nrca.net/rp/technical/files/4898.pdf
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Flashing and sealant dan orourke Roofing System: Home Inspection and Commercial Inspection 4 11-19-2007 05:14 PM
Vent flashing Jeff Eastman Roofing System: Home Inspection and Commercial Inspection 5 10-14-2007 08:26 PM
Unconventional flashing? Clay E White Roofing System: Home Inspection and Commercial Inspection 2 08-04-2007 08:48 PM
vent flashing dan orourke Roofing System: Home Inspection and Commercial Inspection 0 07-20-2007 10:56 AM
Chimney Flashing Warren Alderman Attic Areas: Home Inspection and Commercial Inspection 3 04-06-2007 09:43 AM


All times are GMT -7. The time now is 07:04 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger