Results 1 to 5 of 5
			
		- 
	03-01-2010, 01:23 PM #1 What am I seeing in the smoke chamber What am I seeing in the smoke chamberWB Fireplaces are definitely not my strong point - I just don't see enough of them. 
 
 Picture was taken from just above the damper in a small Rumford style fireplace - probably originally a coal burner - which is now being used to burn wood (one small log at a time).
 
 This is the best picture of the flue I could get, I barely got the camera passed the damper, and I had no access to the top of the chimney which was located on a steep a snow covered roof. Unfortunately, I did not get a usable picture of the firebox, so I grabbed the one attached from the listing.
 
 I'm trying to understand what I'm seeing here: Extremely heavy creosote buildup? Deteriorating parging on the back of the smoke chamber? Deteriorating mortar between the bricks? Something else?
 This FP will get a recommendation for Level II for other reasons, but I would like to better understand what I'm seeing.
 
 Thanks.
 Similar Threads:
 
- 
	03-01-2010, 02:13 PM #2 Re: What am I seeing in the smoke chamber Re: What am I seeing in the smoke chamberThat's a pretty rough flue, and missing mortar and gaps. As a coal burner they were never intended to burn wood to my knowledge. It sure looks like its gonna need upgrading. 
 
 The top of the chimney should have a masonry cap as its current set up is prone to water/freeze damage.
 
 
- 
	03-01-2010, 04:09 PM #3 Re: What am I seeing in the smoke chamber Re: What am I seeing in the smoke chamberThere was obviously a moisture problem before, the cap at the top of the chimney is recent, birdscreen may mean they had more than water issues. 
 
 
- 
	03-01-2010, 04:11 PM #4 Re: What am I seeing in the smoke chamber Re: What am I seeing in the smoke chamberMost imprtantly though, this solid fuel chimney has no flue liner,whether masonary or otherwise. 
 
 
- 
	03-08-2010, 05:11 AM #5 Re: What am I seeing in the smoke chamber Re: What am I seeing in the smoke chamberIt's a parged, unlined flue unsuitable for use. 
 
 If considering relining, make sure you check for the required 4" air space behind the firebox construction. We usually do a level 2 and end up installing an electric fireplace, a gas direct-vent insert with liner(s) or a pellet appliance with liner in these.
 
 Bart
 
 


 
 
					
					
 
				
				
				
					 Reply With Quote
  Reply With Quote 
						
					 Originally Posted by Michael Thomas
 Originally Posted by Michael Thomas
					

Bookmarks