04-15-2009, 05:18 PM #1
Notched Concrete Beam
I have seen lots of notched wood beams but this is the first time I have seen a concrete beam. Notch was more than 20% of depth and there is a crack to the left of the notch. Owner was there and claimed the PO did it but the cut looked pretty fresh to me.
//Rick
Similar Threads:
-
04-15-2009, 06:08 PM #2
Re: Notched Concrete Beam
I doubt there is a "notching and boring table" for concrete beams, in the IRC anyway.
-
04-15-2009, 06:36 PM #3
Re: Notched Concrete Beam
That's not good.
See those two rust bulls-eyes? Those are the ends of the reinforcing steel which was cut in two.
(Okay, the photo has the garage door track hiding where those two bulls-eyes would be, but a concrete beam *IS* going to have reinforcement in it and they would be cut in a notch like that.)
A structural engineer needs to design appropriate repairs for that.
-