1. 04-16-2007
    Views:
    78,803
Page 2 of 8 FirstFirst 12345678 LastLast
Threads 76 to 150 of 597

Forum: Structural Components: Home Inspection and Commercial Inspection

Framing, Bracing, Engineering, Materials ... For Home Inspections & Commercial Inspections

  1. Questionable framing

    Started by Paul Manicone, 01-18-2014 04:17 PM
    • Replies: 59
    • Views: 4,223
    01-28-2014, 06:58 PM Go to last post
  2. Bouncy manufactured I joist floors

    Started by Bill Anglin, 01-07-2014 05:30 PM
    • Replies: 19
    • Views: 3,494
    01-14-2014, 10:15 AM Go to last post
  3. FRaming cantiliver question

    Started by ren ramsey, 01-08-2014 01:29 PM
    • Replies: 8
    • Views: 1,569
    01-10-2014, 10:12 AM Go to last post
  4. Lintel Weep Holes

    Started by George2, 08-12-2013 03:17 PM
    • Replies: 8
    • Views: 3,670
    01-09-2014, 04:20 AM Go to last post
  5. Water level (Manometer)

    Started by Martin lehman, 05-22-2007 09:02 PM
    • Replies: 19
    • Views: 9,103
    12-07-2013, 03:45 PM Go to last post
  6. Fire wall / multi-family

    Started by Jerome W. Young, 12-21-2007 10:00 AM
    • Replies: 10
    • Views: 13,204
    11-01-2013, 04:26 AM Go to last post
  7. Joist Hangers in Basement

    Started by Eric Delio, 10-21-2013 07:42 AM
    • Replies: 6
    • Views: 2,247
    10-27-2013, 10:32 AM Go to last post
  8. Do these floor trusses need studs under them

    Started by ren ramsey, 10-03-2013 01:02 PM
    • Replies: 4
    • Views: 1,888
    10-05-2013, 07:12 AM Go to last post
  9. LVL not supported on ends & twisted

    Started by Sam Morris, 09-30-2013 04:24 PM
    • Replies: 3
    • Views: 1,308
    09-30-2013, 09:30 PM Go to last post
  10. 2 story, 2x4 stud walls

    Started by Chris Weekly, 09-18-2013 04:57 PM
    • Replies: 11
    • Views: 4,373
    09-30-2013, 02:48 PM Go to last post
  11. cracks in the living room slab.

    Started by unknown 123, 09-21-2013 05:53 PM
    • Replies: 18
    • Views: 3,497
    09-28-2013, 04:02 AM Go to last post
  12. Vault construction details

    Started by Rick Cantrell, 09-14-2013 06:07 PM
    • Replies: 3
    • Views: 1,391
    09-27-2013, 08:38 PM Go to last post
  13. Bowed interior wall on a A-Frame House

    Started by Sam Morris, 09-09-2013 05:39 PM
    • Replies: 9
    • Views: 2,382
    09-23-2013, 11:03 AM Go to last post
  14. Open beam ceiling

    Started by Chris Weekly, 09-16-2013 08:24 PM
    • Replies: 10
    • Views: 2,175
    09-21-2013, 06:33 AM Go to last post
  15. Moisture Basement Wall

    Started by George2, 08-12-2013 04:08 PM
    • Replies: 4
    • Views: 1,719
    09-03-2013, 08:53 AM Go to last post
  16. Angry Big ol' deck attachment

    Started by Chris Weekly, 08-24-2013 01:46 PM
    • Replies: 18
    • Views: 2,094
    08-31-2013, 05:43 AM Go to last post
  17. New slab connection to old pier-and-beam

    Started by Tim Kallmer, 08-04-2013 01:25 PM
    • Replies: 7
    • Views: 4,819
    08-17-2013, 10:28 PM Go to last post
  18. Lintel and mortar type

    Started by Susan l, 07-30-2013 12:34 PM
    • Replies: 7
    • Views: 1,718
    08-03-2013, 04:00 PM Go to last post
  19. Garage Ceiling Storage Rack

    Started by Chris Stichter, 06-20-2013 04:47 PM
    • Replies: 12
    • Views: 2,610
    06-24-2013, 08:26 AM Go to last post
  20. FLOOR JOIST to ADDITION SEEM UNSOUND

    Started by Sam Morris, 06-19-2013 05:15 PM
    • Replies: 7
    • Views: 2,268
    06-22-2013, 12:38 PM Go to last post
  21. Painted Crawlspace

    Started by Lon Henderson, 06-07-2013 06:34 AM
    • Replies: 13
    • Views: 5,707
    06-19-2013, 05:32 PM Go to last post
    • Replies: 2
    • Views: 2,187
    06-07-2013, 05:57 PM Go to last post
  22. Bad Idea

    Started by Lon Henderson, 05-29-2013 08:59 AM
    • Replies: 10
    • Views: 2,418
    06-04-2013, 06:08 AM Go to last post
  23. Dark spots on the foundation.

    Started by Eli Smith, 05-30-2013 03:34 AM
    • Replies: 14
    • Views: 3,291
    05-31-2013, 12:41 PM Go to last post
  24. Post to beam connection - deck

    Started by Bill Penn, 09-12-2012 06:19 AM
    • Replies: 18
    • Views: 13,514
    05-03-2013, 03:58 PM Go to last post
  25. Beam ends cut short?

    Started by Chris Weekly, 04-27-2013 02:31 PM
    • Replies: 11
    • Views: 3,132
    05-01-2013, 04:20 PM Go to last post
  26. Question Metal Lintel Above Garage Doors

    Started by Reggie Russell, 04-22-2010 07:05 PM
    • Replies: 25
    • Views: 15,309
    04-28-2013, 07:39 AM Go to last post
  27. Don't like these trusses

    Started by Ernie Simpson, 04-12-2013 09:37 AM
    • Replies: 5
    • Views: 2,440
    04-19-2013, 06:08 AM Go to last post
  28. Concrete slab crack in living room

    Started by alex00, 04-08-2013 09:12 PM
    • Replies: 8
    • Views: 3,501
    04-15-2013, 04:29 AM Go to last post
  29. COMPROMISED CEILING/FLOOR JOIST

    Started by CHARLIE VAN FLEET, 04-04-2013 07:51 AM
    • Replies: 5
    • Views: 2,328
    04-05-2013, 08:57 AM Go to last post
  30. Cider block floors with concrete floor joist

    Started by Sam Morris, 03-12-2013 05:58 PM
    • Replies: 5
    • Views: 2,688
    04-04-2013, 05:00 AM Go to last post
    • Replies: 14
    • Views: 10,926
    03-04-2013, 03:14 PM Go to last post
  31. Would you tell your client to run?

    Started by Ken Amelin, 02-10-2013 05:17 AM
    • Replies: 13
    • Views: 2,021
    02-13-2013, 07:58 AM Go to last post
  32. Smile Holes in stair risers?

    Started by Mitchell Chiger, 01-24-2013 08:09 AM
    • Replies: 2
    • Views: 1,971
    02-04-2013, 07:49 PM Go to last post
  33. Interior basement stairs question

    Started by Bill Anglin, 02-01-2013 11:37 AM
    • Replies: 13
    • Views: 3,593
    02-04-2013, 02:32 PM Go to last post
    • Replies: 3
    • Views: 1,517
    01-24-2013, 05:14 PM Go to last post
  34. Trap under Concrete

    Started by Rich Goeken, 01-04-2013 05:46 AM
    • Replies: 20
    • Views: 14,139
    01-19-2013, 10:47 AM Go to last post
  35. Framing supports under roof rafters

    Started by mathew stouffer, 01-17-2013 08:40 PM
    • Replies: 7
    • Views: 2,344
    01-18-2013, 02:06 PM Go to last post
  36. 2x4 main beam ?

    Started by Sam Morris, 01-04-2013 06:51 PM
    • Replies: 24
    • Views: 3,176
    01-09-2013, 09:42 PM Go to last post
  37. notching

    Started by Marc M, 01-01-2013 04:59 PM
    • Replies: 18
    • Views: 1,913
    01-05-2013, 02:23 PM Go to last post
  38. A sign I haven't seen yet

    Started by Marc M, 10-19-2012 09:13 PM
    • Replies: 9
    • Views: 1,647
    12-28-2012, 07:21 AM Go to last post
  39. Classy Beam Work

    Started by Jim Robinson, 12-17-2012 01:50 PM
    • Replies: 8
    • Views: 1,226
    12-19-2012, 01:27 PM Go to last post
  40. Question I beam installation issue

    Started by JamesJW, 12-08-2012 01:27 PM
    • Replies: 9
    • Views: 2,096
    12-11-2012, 01:49 PM Go to last post
  41. Girder ends

    Started by Jeffrey L. Mathis, 12-10-2012 02:47 PM
    • Replies: 3
    • Views: 966
    12-11-2012, 06:09 AM Go to last post
  42. How long have CMU's been around?

    Started by Luc V. L., 11-26-2012 07:40 PM
    • Replies: 14
    • Views: 2,596
    12-07-2012, 04:47 AM Go to last post
  43. Interesting floor system

    Started by Jack Feldmann, 12-01-2012 01:29 PM
    • Replies: 22
    • Views: 1,838
    12-03-2012, 07:54 PM Go to last post
  44. Too much notch?

    Started by Marc M, 11-08-2012 09:15 PM
    • Replies: 23
    • Views: 2,074
    11-29-2012, 05:45 PM Go to last post
  45. Question open vs closed foundation for stairs

    Started by Gerry Wang, 11-09-2012 10:03 PM
    • Replies: 1
    • Views: 1,648
    11-13-2012, 07:40 PM Go to last post
  46. Do I need a structural engineer?

    Started by Krishna Kothamasu, 11-10-2012 10:14 AM
    • Replies: 6
    • Views: 1,503
    11-10-2012, 04:12 PM Go to last post
  47. Squeak Preventer?

    Started by Michael Chambers, 10-31-2012 10:21 AM
    • Replies: 4
    • Views: 1,034
    10-31-2012, 11:20 PM Go to last post
  48. Is this Sheating up to Code

    Started by mattjung, 10-28-2012 05:41 AM
    • Replies: 12
    • Views: 1,634
    10-31-2012, 04:23 PM Go to last post
  49. How tell if the wood is pressure treated

    Started by mattjung, 10-28-2012 08:08 PM
    • Replies: 9
    • Views: 24,374
    10-31-2012, 03:40 PM Go to last post
  50. Weak Concrete Pad and weak joists

    Started by Netlinks Communications, 10-26-2012 02:13 PM
    • Replies: 13
    • Views: 1,778
    10-30-2012, 08:26 AM Go to last post
  51. Would you call the country inspector in?

    Started by Ron Bibler, 07-29-2012 06:12 PM
    • Replies: 21
    • Views: 2,339
    10-22-2012, 07:58 AM Go to last post
  52. Tall Storey

    Started by Aaron Miller, 09-20-2012 03:03 AM
    • Replies: 2
    • Views: 1,491
    09-21-2012, 09:41 AM Go to last post
  53. Exterior sheathing, local Dallas area codes ?

    Started by John Dallas, 09-16-2012 02:12 PM
    • Replies: 2
    • Views: 1,670
    09-19-2012, 04:24 AM Go to last post
  54. Trusses spaced 4' apart?

    Started by Bill Anglin, 09-15-2012 11:21 AM
    • Replies: 14
    • Views: 7,178
    09-18-2012, 05:38 PM Go to last post
  55. Log house

    Started by Mark Fisher, 09-15-2012 01:09 PM
    • Replies: 1
    • Views: 781
    09-15-2012, 03:00 PM Go to last post
  56. Welded pipe residential framing

    Started by Marc Robin, 09-08-2012 02:06 PM
    • Replies: 2
    • Views: 1,083
    09-09-2012, 09:17 AM Go to last post
  57. Floor squeaks and drywall cracks

    Started by Ken Rowe, 08-30-2012 09:57 PM
    • Replies: 22
    • Views: 3,367
    09-05-2012, 01:39 PM Go to last post
  58. Strapping for Manufactured Homes in Florida

    Started by Brian Harwood, 08-30-2012 03:43 PM
    • Replies: 10
    • Views: 2,189
    08-31-2012, 03:56 PM Go to last post
  59. Corrosion on jacks under manufactured home

    Started by Bill Anglin, 07-28-2012 07:44 PM
    • Replies: 26
    • Views: 3,829
    08-26-2012, 06:42 PM Go to last post
  60. Boise Versa Lam

    Started by mathew stouffer, 08-15-2012 06:48 PM
    • Replies: 5
    • Views: 1,237
    08-16-2012, 04:41 AM Go to last post
  61. Black Joists - Really Black?

    Started by Mike Gault, 07-24-2012 03:25 PM
    • Replies: 15
    • Views: 3,026
    08-02-2012, 06:06 AM Go to last post
  62. Attic framing

    Started by mathew stouffer, 07-24-2012 06:27 AM
    • Replies: 11
    • Views: 1,534
    07-24-2012, 08:12 PM Go to last post
  63. Nightmare Roof Framing on Addition

    Started by Brian Harwood, 07-17-2012 12:42 PM
    • Replies: 5
    • Views: 1,507
    07-21-2012, 06:23 PM Go to last post
  64. block wall crack poll

    Started by John Arnold, 07-19-2012 06:57 AM
    • Replies: 9
    • Views: 1,733
    07-20-2012, 08:12 PM Go to last post
  65. Spiral staircase with open risers

    Started by Ken Amelin, 07-16-2012 04:32 AM
    • Replies: 1
    • Views: 1,209
    07-17-2012, 07:45 AM Go to last post
  66. Steel Support Beams

    Started by Steve Slaughter, 06-15-2012 07:10 PM
    • Replies: 15
    • Views: 5,874
    07-17-2012, 07:29 AM Go to last post
  67. Allowable bow in a stud

    Started by Mike Schulz, 07-09-2012 06:44 AM
    • Replies: 1
    • Views: 1,399
    07-09-2012, 07:29 AM Go to last post
    • Replies: 5
    • Views: 1,438
    06-30-2012, 07:09 PM Go to last post
  68. Uh-oh !

    Started by Jim Hintz, 06-21-2012 12:36 PM
    • Replies: 0
    • Views: 818
    06-21-2012, 12:36 PM Go to last post
    • Replies: 1
    • Views: 2,373
    06-18-2012, 09:10 PM Go to last post
  69. beam's colons on first floor's floor.

    Started by Eli Smith, 05-21-2012 09:27 PM
    • Replies: 12
    • Views: 2,026
    05-31-2012, 11:05 PM Go to last post
    • Replies: 3
    • Views: 1,917
    05-21-2012, 08:40 AM Go to last post

Page 2 of 8 FirstFirst 12345678 LastLast

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •