You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

05-31-2007, 10:37 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,185
|
|
|
crack of the month
Older structural brick - not veneer. Can't really see the lateral displacement and bulging so well in the photos. This is the worst I've seen in quite a while. Not sure how to fix, but then that's not my job.
|
|

05-31-2007, 11:10 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 663
|
|
|
Re: crack of the month
It's already been repaired. See the earthquake rod? That will hold the brick in place (i.e., keep the brick from moving out on this and the opposite face). Earthquake rods installed perpendicular to this one will help keep this crack from widening.
Actually, while earthquake rods are a big improvement they are not the final solution. I remember seeing earthquake rods on many old brick buildings in Charleston. Not sure how effective they are in a large earthquake but they were probably cutting-edge techology in earthquake-proofing buildings circa 1890.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

05-31-2007, 11:39 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Southborough, MA
Posts: 912
|
|
|
Re: crack of the month
__________________
Dave
|
|

05-31-2007, 11:50 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 699
|
|
|
Re: crack of the month
I think the cause of that crack is quite apparent.........that pen is forcing the wall apart. If you remove the pen, everything should go back to normal  .
|
|

05-31-2007, 12:20 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,185
|
|
|
Re: crack of the month
Nick - You know what they say: the pen is mightier than the ... star anchor?
|
|

05-31-2007, 12:27 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,543
|
|
|
Re: crack of the month
We never called them "earthquake rods", but installed them to help retain the outer wythe of brick walls on a few older homes. We simply called them tie backs and stars anchors.
I like the explanation given in the link David provided, but settlement can also cause variations of that bulging.
|
|

05-31-2007, 01:15 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 663
|
|
|
Re: crack of the month
My response was about 90% tongue-in-cheek.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

05-31-2007, 02:15 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,543
|
|
|
Re: crack of the month
Originally Posted by Bruce Breedlove
My response was about 90% tongue-in-cheek.
In Gainesville, Florida, we had some old brick structures, many had those tie backs and stars installed to retain the brick walls from movement/bulging/etc.
Thus I did not make the 90% connection. 
|
|

05-31-2007, 06:34 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Barrington, IL
Posts: 356
|
|
|
Re: crack of the month
Sometimes the anchors work and sometimes they don't.
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
|
|

05-31-2007, 07:27 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,543
|
|
|
Re: crack of the month
Originally Posted by Eric Barker
Sometimes the anchors work and sometimes they don't.
Yep. I've seen that too.
|
|

05-31-2007, 08:23 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 582
|
|
|
Re: crack of the month
The engineer agreed this crack did not need repairs.
__________________
The only reason some people get lost in thought is because it's unfamiliar territory.
- Paul Fix
|
|

05-31-2007, 08:28 PM
|
|
Member
|
|
Join Date: May 2007
Location: NC
Posts: 461
|
|
|
Re: crack of the month
Yep....don't need repair but sure needs me! 
|
|

06-01-2007, 05:42 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Indianapolis, Indiana
Posts: 336
|
|
|
Re: crack of the month
Correct me if I am wrong, but with that wall type, shouldn't there be cross ties every 6 rows?
By the way, Thom, would advise to cover and hide that crack. Major safety concern.
"In the news today, an amish waoman and her 6 childred died when the husband (father) veered his carriage into traffic while looking at a road side sign. Man survived, but is said to be going blind."
__________________
Integrity Inspection Service, LLC
www.irsindy.com
(317) 345-1828
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Crack in foundation |
Jeff Eastman |
Structural Components: Home Inspection and Commercial Inspection |
15 |
05-22-2007 12:15 PM |
| May Is National Electrical Safety Month: |
Brian Hannigan |
Electrical Systems: Home Inspection and Commercial Inspection |
0 |
05-10-2007 09:28 AM |
| May is Deck Safety Month |
Brian Hannigan |
Exterior Systems: Home Inspection and Commercial Inspection |
2 |
05-02-2007 05:32 AM |
| Crack in the wall |
Mike Huppi |
Building Interior: Home Inspection and Commercial Inspection |
17 |
04-18-2007 11:44 AM |
| caulk that crack says SE |
John Arnold |
Structural Components: Home Inspection and Commercial Inspection |
6 |
04-12-2007 01:33 PM |
All times are GMT -7. The time now is 12:54 PM.
| | |
|