You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 06-02-2007, 08:42 AM
dan orourke dan orourke is offline
Member
 
Join Date: Mar 2007
Location: dust in the wind
Posts: 157
Gutter discharge
..........

Last edited by dan orourke : 01-02-2008 at 08:08 AM.
Reply With Quote
Are inspection referrals from past clients important to you? If so, click here to get even more referrals!
  #2 (permalink)  
Old 06-02-2007, 09:34 AM
Ed Ochs's Avatar
Ed Ochs Ed Ochs is offline
Member
 
Join Date: Apr 2007
Location: Wisconsin
Posts: 7
Re: Gutter discharge
Dan,
This downspout is a bigger problem than having another 90 to help it shed water (right now it will push under shingles) so to answer your question yes bad idea...even better would be to get downspout to terminate in that lower gutter for discharge
Reply With Quote
  #3 (permalink)  
Old 06-02-2007, 06:06 PM
Jon Randolph Jon Randolph is offline
Member
 
Join Date: Mar 2007
Location: Indianapolis, Indiana
Posts: 339
Re: Gutter discharge
The roofing will wear quicker in that area as the increased and concentrated ater flow will dislodge the granules more quickly. Also as Ed stated, the water could be directed under the adjacent shingles. Better to discharge the water to the downspout below, or even better to the ground.
__________________
Integrity Inspection Service, LLC
www.irsindy.com
(317) 345-1828
Reply With Quote
  #4 (permalink)  
Old 06-02-2007, 06:32 PM
Thom Walker's Avatar
Thom Walker Thom Walker is offline
Member
 
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 582
Re: Gutter discharge
I would guess that if that is an upside down shingle placed there, that a leak was already detected. It appears that no kick out flashing was employed. And did the siding come into contact with the shingles or were you looking at flashing along that wall.
I'm not aware of code addressing this specific issue. R801.3 addresses general roof drainage, which this house may not have met either. I don't know the soil type based on this picture, but if it is expansive or collapsible soil, that downspout pictured should have termiinated at least 5 feet away from the building.
Re: that 90, turn it around. I'm npt seein any pitch on the gutter. Was there?
__________________
The only reason some people get lost in thought is because it's unfamiliar territory.
- Paul Fix
Reply With Quote
  #5 (permalink)  
Old 06-02-2007, 07:43 PM
James Duffin James Duffin is offline
Member
 
Join Date: May 2007
Location: NC
Posts: 470
Re: Gutter discharge
I always suggest that a metal splash diverter be installed to minimize deterioration to the roof surface where the gutter dumps on a roof surface. It is considered an improvement and nobody does it but I think it is a good idea.
Reply With Quote
  #6 (permalink)  
Old 06-04-2007, 08:17 AM
Robert Schenck's Avatar
Robert Schenck Robert Schenck is offline
Member
 
Join Date: Mar 2007
Location: Northern California
Posts: 44
Re: Gutter discharge
I see a lot of this myself. Although I don't know of any "Code" requirement for the builder to bring the downspout to the gutter, I always recommend to the buyer to bring it down to the gutter to prevent premature wear on the shingles.
Attached Images
File Type: jpg Sample Pic.JPG (87.3 KB, 31 views)
__________________
Robert
Roberts Home Inspection Service
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Extra discharge pipe Scott Dana Plumbing System: Home Inspection and Commercial Inspection 12 05-25-2007 02:44 PM


All times are GMT -7. The time now is 09:16 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger