|
|
|
Welcome to the InspectionNews - Home Inspection forums.
You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

10-09-2007, 02:36 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,423
|
|
|
Ceiling Joist and Rafter connection
I just did a pre-drywall inspection and came away shaking my head. There was not a ceiling joist tied to a rafter or any substitute such as metal straps anywhere in the structure. Are any of the guys in the Dallas area having this sort of thing on the bigger homes? This was one of the roofs with multiple hip/valleys and sloped ceilings in the upstairs bedrooms, etc. Actually the workmanship was pretty fair on most of the framing, but very poorly designed for any resistance to rafter thrust. Just wanting to compare notes, I have already called for an engineer to get involved.
Thanks, Jim
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
|
|

10-09-2007, 02:52 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Barrington, IL
Posts: 356
|
|
|
Re: Ceiling Joist and Rafter connection
Jim, I'll assume that there is no structural beam at the ridge. Load transfer is always a consideration for me and if something seems lacking then I question it. For some reason, I have noticed that when a poorly framed home reaches 25 - 30 years the signed of sagging/deflected framing begins to become apparent. If I have a situation where a condition is in question, and I cannot satisfy my concern, then I report it is such. For example, "Could not confirm proper fastening of joist/rafter junctions."
Of course I really want to be sure such a statement is warranted and that I haven't missed something before I write a comment like that.
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
|
|

10-09-2007, 04:40 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Land of Gar, TX
Posts: 391
|
|
|
Re: Ceiling Joist and Rafter connection
Jim,
Any pix?
__________________
badair http://www.adairinspection.com Garland, TX 75042
Residential-Commercial-Construction-EIFS-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes
|
|

10-09-2007, 05:29 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,423
|
|
|
Re: Ceiling Joist and Rafter connection
Barry, I took 154 photos and did not get one good shot to show any perspective. The multi-level ceiling and chopped up roof made it nearly impossible to trace any load path while I was there in person much less get a good shot for my report. I will look through and see if I can piece enough together to post here.
Jim
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
|
|

10-09-2007, 05:42 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,423
|
|
|
Re: Ceiling Joist and Rafter connection
See if you can make this out, as I said earlier, I could not get any really clear shots.
The last shot looking down at my feet shows the end of the stiff back over the garage from the previous shot that stops at the perpendicular ceiling joist, the entire gable end wall and the roof up over the second story has nothing to resist rafter thrust.
Also, Notice the beam in the right of the third shot, I could not see any adequate provision to keep the beam from rotating and kicking the 2x4 legs out. Am I just paranoid?
Jim
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
Last edited by Jim Luttrall : 10-09-2007 at 05:51 PM.
|
|

10-09-2007, 06:09 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Barrington, IL
Posts: 356
|
|
|
Re: Ceiling Joist and Rafter connection
Rotation certainly a possibility. Also, look where they transfer the load to - a doubled top plate with no support directly underneath.
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
|
|

10-09-2007, 06:58 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,067
|
|
|
Re: Ceiling Joist and Rafter connection
No collar ties either.
For reference about the other photo.
|
|

10-09-2007, 08:38 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Land of Gar, TX
Posts: 391
|
|
|
Re: Ceiling Joist and Rafter connection
Jim, good call
yo no entiendo para mí corregirlo costó más dinero
__________________
badair http://www.adairinspection.com Garland, TX 75042
Residential-Commercial-Construction-EIFS-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| alternating joist sizes |
John Arnold |
Structural Components: Home Inspection and Commercial Inspection |
4 |
05-26-2007 10:49 AM |
| Joist span |
wayne soper |
Exterior Systems: Home Inspection and Commercial Inspection |
2 |
05-18-2007 12:08 PM |
| Exposed wood joist in return air |
John Tullous |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
15 |
05-08-2007 06:27 PM |
| Scissor joist |
Mike Schulz |
Sub-Structure: Home Inspection and Commercial Inspection |
9 |
04-11-2007 08:41 PM |
| Joist support |
Francis Turak |
Structural Components: Home Inspection and Commercial Inspection |
14 |
04-04-2007 06:15 PM |
All times are GMT -7. The time now is 09:16 AM.
| | |
|