You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 01-25-2008, 03:49 PM
Wendell Swedberg Wendell Swedberg is offline
Member
 
Join Date: Dec 2007
Location: phoenix
Posts: 47
Structural Engineering Question
............

Last edited by Wendell Swedberg : 03-01-2008 at 07:20 PM.
Reply With Quote
  #2 (permalink)  
Old 01-26-2008, 09:09 AM
wayne soper's Avatar
wayne soper wayne soper is offline
Member
 
Join Date: Mar 2007
Location: Connecticut
Posts: 725
Re: Structural Engineering Question
How do you know there are no lintels?,
What are appropriate deflection tolerances?
Do you own a camera?
Reply With Quote
  #3 (permalink)  
Old 01-26-2008, 03:38 PM
Randy Aldering Randy Aldering is offline
Member
 
Join Date: Mar 2007
Location: Michigan
Posts: 152
Re: Structural Engineering Question
Based on the limited information, neither are structural in nature. Consider a problem with the mortar mix, or conditions during application.
__________________
Randy Aldering, RHI CHI
Housesmithe Home Inspection
www.housesmithe.com
Reply With Quote
  #4 (permalink)  
Old 01-26-2008, 06:10 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,071
Re: Structural Engineering Question
Quote:
Originally Posted by Wendell Swedberg View Post
He said that cracks in masonry above garage / doors/windows that are square (with lintels) are non structural defects.
I can show him a building several blocks from my office where oxide jacking at the lintels is lifting the entire second and third stories of a half-block long Chicago structural masonry 1920's apartment building converted to condos up and out - it's costing the association around a three quarters of a million dollars to stabilize and repair. Extreme case admittedly, but the only obvious indication at the exterior was "cracks above the lintels of square windows"....
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #5 (permalink)  
Old 01-26-2008, 07:52 PM
Jerry S Simon Jerry S Simon is offline
Member
 
Join Date: Apr 2007
Location: Chicago
Posts: 2
Re: Structural Engineering Question
Quote:
Originally Posted by Michael Thomas View Post
I can show him a building several blocks from my office where oxide jacking at the lintels is lifting the entire second and third stories of a half-block long Chicago structural masonry 1920's apartment building converted to condos up and out - it's costing the association around a three quarters of a million dollars to stabilize and repair. Extreme case admittedly, but the only obvious indication at the exterior was "cracks above the lintels of square windows"....
Oxide-Jacking...what a cool term. Seen it plenty, but never knew the *technical* term. Yeah, it appears to have as much lift-power as does frost (physics.... another cool thingy).

That much $ to bolster/replace the lintels & tuck-point? Must be lots o' lintels...
Reply With Quote
  #6 (permalink)  
Old 01-26-2008, 08:40 PM
Eric Barker's Avatar
Eric Barker Eric Barker is offline
Member
 
Join Date: Mar 2007
Location: Barrington, IL
Posts: 356
Re: Structural Engineering Question
Wendell,

I think that the PE veered off course when he made a blanket statement that cracks over square openings are not a problem.

I looked at a 1 yr old 2 story last month. Brick veneer corner of second floor centered over O.H. door. Top of door opening is sagging, cracks from door up to roof. Homeowner is taking the builder to court. Prior to building this home the builder was banned from construction in the village (Glenview) for one year due to lousy workmanship.

It seems that a header wasn't part of the framing game plan. They also skipped squash blocks - virtually the entire basement ceiling was just re-drywalled. This due to a slight plumbing problem on the second floor from poor installation.

Apparently the builder didn't forget his tricks of the trade - or learn any new ones - while he was on leave.
Attached Images
File Type: jpg Deflection.JPG (68.7 KB, 55 views)
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
Reply With Quote
  #7 (permalink)  
Old 01-29-2008, 02:04 PM
Randy Aldering Randy Aldering is offline
Member
 
Join Date: Mar 2007
Location: Michigan
Posts: 152
Re: Structural Engineering Question
Wendell;

Perhaps the P.E. was pulling your leg. Making generalizations such as the ones he made are inappropriate. That is why site visits are necessary to determine what is happening. Answer the P.E.'s question with another:

Would a P.E. make such a determination without additional information collected from a site visit, and possibly looking at blueprints of the original construction, if they are still available?
__________________
Randy Aldering, RHI CHI
Housesmithe Home Inspection
www.housesmithe.com
Reply With Quote
  #8 (permalink)  
Old 01-30-2008, 09:55 AM
Brandon Chew Brandon Chew is offline
Member
 
Join Date: Mar 2007
Location: Albany, NY
Posts: 258
Re: Structural Engineering Question
Quote:
Originally Posted by Randy Aldering View Post
Would a P.E. make such a determination without additional information collected from a site visit, and possibly looking at blueprints of the original construction, if they are still available?
That's the reason why I haven't jumped into this thread. My answer to the original question is "it depends" ... and not enough info is provided to conclude that either one is, or is not, a structural issue.
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Structural Settlement or Structural Failure? K Lucas Structural Components: Home Inspection and Commercial Inspection 14 11-29-2007 07:05 PM
Inspect for Engineering Company Gregory Parsons Employment: Home Inspectors & Commercial Inspectors 0 11-08-2007 05:58 AM
Slab-on-Grade Engineering Required? Aaron Miller Sub-Structure: Home Inspection and Commercial Inspection 4 09-30-2007 09:51 AM
Cracks, cosmetic or structural RobertSmith Building Interior: Home Inspection and Commercial Inspection 10 07-14-2007 03:17 PM
Anatomy of a Structural Failure Nick Ostrowski Structural Components: Home Inspection and Commercial Inspection 2 06-08-2007 12:32 PM


All times are GMT -7. The time now is 07:18 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger