Results 1 to 15 of 15
  1. #1
    Join Date
    Mar 2007
    Location
    Charleston, WV
    Posts
    77

    Default Foundation Waterproofing

    Do we have any experts on Foundation Drainage Panels. In the posted picture you will see what I think is a dimpled geomat waterpoofing system for the below grade foundation walls.
    Should this material have been cut evenly with the top of the foundation wall and sealed? Is there a chance of water getting behind it in its current condition?
    This is new construction. The house was just recently completed.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    OREP Insurance
    Greg Jenkins

  2. #2
    Jon Randolph's Avatar
    Jon Randolph Guest

    Default Re: Foundation Waterproofing

    I have never seen this material and know nothing about it so there is little or actually no experience behind the following statement.

    It seems to me that it was installed backwards. I would think that you would want the groved side facing the foundation to create a channel for any water to run down and into the perimeter drainage system. The channels, as this is installed, are plugged with dirt and mulch so I don't see how it would be any better than a water proof sheeting.


  3. #3
    Join Date
    Mar 2007
    Location
    Myrtle Beach, South Carolina
    Posts
    341

    Default Re: Foundation Waterproofing

    Bingo, Jon....

    " its stud-shaped dimples provide an air chamber between the roll and wall, keeping walls dry. The dimples are aligned along vertical and horizontal axis to rapidly channel water from grade to the footer drainage system"

    Mar-Flex: Geo-Mat Products

    Critical Home Inspection Services
    www.Home2Spec.com

  4. #4
    Join Date
    Mar 2007
    Location
    Myrtle Beach, South Carolina
    Posts
    341

    Default Re: Foundation Waterproofing

    Oops...spoke too soon....
    then there's this product....


    http://www.amvic-pacific.com/Downloa...0Basements.pdf

    "After application of either an approved waterproofing membrane or a liquid waterproofing compound, unroll

    the Protecto Drain 2000-V and place against the surface with the flat side of the panel facing the wall"

    http://www.amvic-pacific.com/Downloa...rain-2000V.pdf

    So.... Greg, not having x-ray vision, I can't comment on what's below grade. However, what is visible, appears to be improperly terminated, and looks like it will allow water to run behind the dimple board, defeating it's purpose.


    Last edited by Victor DaGraca; 06-07-2008 at 04:47 PM.
    Critical Home Inspection Services
    www.Home2Spec.com

  5. #5
    Join Date
    Mar 2007
    Location
    Healdsburg, CA
    Posts
    1,741

    Default Re: Foundation Waterproofing

    Greg, not the same material, but similar and properly attached.
    Had a law suit where it was not and a case I lost as the EW for a large GC. They paid over 350K for water damage.

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Jerry McCarthy
    Building Code/ Construction Consultant

  6. #6
    Jon Randolph's Avatar
    Jon Randolph Guest

    Default Re: Foundation Waterproofing

    Quote Originally Posted by Jerry McCarthy View Post
    not the same material, but similar and properly attached.
    Jerry,

    I'm not interrogating you as I have no experience with it, but it seems wrong. Are you saying that the material in Greg's picture above IS installed correctly?


  7. #7
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: Foundation Waterproofing

    The *other* Jerry here ... *to me* it looks like the material in the photo is not applied correctly. WC Jerry was showing a different product in his photo.

    This is from the Geo-Mat web site: (underlining is mine)

    "Mar-flex Geo-Mat Products are designed for various applications. Geo-Mat is a dampproofing drainage roll, Geo-Mat Plus is a protection and drainage roll used in conjunction with Mar-flex’s waterproofing membranes to form a complete system, and Mar-flex Geo-Mat accessories are used to professionally complete any job."

    "In conjunction with ... waterproofing membranes"

    Was there a waterproofing membrane applied?

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  8. #8
    Join Date
    Feb 2008
    Location
    High Point, NC
    Posts
    97

    Default Re: Foundation Waterproofing

    I installed this material on my new home 4 years ago.
    Victor's explanation of how it is to be installed with the silt screen on the outside and the dimples against the wall is correct.
    The mat only helps channel water to the drainage system. Otherwise, it does nothing for water proofing a wall. It should be installed with an adhesive.
    The builder wasted a lot of money on installing the mat "wrong side out".
    I would report this to my client and recommend correction, as costly as that may be. In addition, if the builder got this wrong what else did he miss?
    I think this materal works very well when correctly installed. You can place this over any other coatings you have applied.
    Another dumb builder story.


  9. #9
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: Foundation Waterproofing

    Quote Originally Posted by Tom Edwards View Post
    place this over any other coatings you have applied.
    That was the manufacturer's point I was raising - that this material is a "drainage plane", not "waterproofing". It needs to be applied over "waterproofing".

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  10. #10
    Join Date
    Mar 2007
    Location
    Charleston, WV
    Posts
    77

    Default Re: Foundation Waterproofing

    Here is another picture of the same house but at a different location along the foundation wall.
    Since I was not familiar with this product I did not know what to look for at the time of the inspeciton. Now I am looking at this second picture and I can not tell which side the dimples are on.
    Can any of your trained eyes figure it out?

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Greg Jenkins

  11. #11
    Join Date
    Mar 2007
    Location
    Charleston, WV
    Posts
    77

    Default Re: Foundation Waterproofing

    Also, it looks like there is fabric between the mat and the soil.

    Greg Jenkins

  12. #12
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: Foundation Waterproofing

    Greg,

    That photo shows a different product, however, the intent would be the same.

    The top show be closed off, though.

    The purpose is to create drainage channels for water which seeps/weeps through the soil to gravity drain down to the drainage channel at the bottom.

    Allowing more water in at the top (with the top being left open) only adds more water to the drainage system which must then be drained away.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  13. #13
    Join Date
    Mar 2007
    Location
    Charleston, WV
    Posts
    77

    Default Re: Foundation Waterproofing

    So, In summary: The pictures are of two different drainage plane products. Both appear to be improperly terminated or sealed at the top. One (the first picture) may possibly be improperly installed with the dimples facing the wrong directions. Of course, all of this is assuming these are not just scrap pieces left behind during backfill.
    It sounds like my client should request some excavation for further investigation as well as some product information and assurance from the builder that these products are installed properly.
    Thanks for all the input.

    Greg Jenkins

  14. #14
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: Foundation Waterproofing

    From what I can see in the photos:

    Quote Originally Posted by Greg Jenkins View Post
    So, In summary: The pictures are of two different drainage plane products.
    Yes, they look like different products in the photos.

    Both appear to be improperly terminated or sealed at the top.
    Yes, from what I can see.

    One (the first picture) may possibly be improperly installed with the dimples facing the wrong directions.
    Yes.

    Of course, all of this is assuming these are not just scrap pieces left behind during backfill.
    Correct.

    It sounds like my client should request some excavation for further investigation as well as some product information and assurance from the builder that these products are installed properly.
    Agreed.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  15. #15
    Join Date
    Feb 2008
    Location
    Chicago IL
    Posts
    2,048

    Default Re: Foundation Waterproofing

    The material shown in the pictures looks like the stuff typically used around here when installing a 'french drain' tied to a sump pit.
    Installation looks sloppy. I find it doubtful that that material as shown could act as a 'waterproofing' membrane.
    Just my thoughts.

    www.aic-chicago.com
    773/844-4AIC
    "The Code is not a ceiling to reach but a floor to work up from"

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •