You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-12-2008, 12:33 PM
wayne soper's Avatar
wayne soper wayne soper is offline
Member
 
Join Date: Mar 2007
Location: Connecticut
Posts: 725
Block piers
My brains not working and I can't find the height code for concrete block piers.
I'm remembering anything over three high requires double but can't find the section.
Thanks in advance, Wayne
Here's the reason for the question.
Attached Images
File Type: jpg Louise's Lane 066.jpg (50.6 KB, 81 views)
Reply With Quote
Home inspection
  #2 (permalink)  
Old 07-12-2008, 01:47 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 777
Re: Block piers
Ten times there least dimension

IRC 2000

R606.5 Piers
__________________
Ted Menelly
"Castle"
Home Inspection Services

Last edited by Ted Menelly : 07-12-2008 at 02:02 PM.
Reply With Quote
  #3 (permalink)  
Old 07-12-2008, 02:01 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 777
Re: Block piers
The unsupported height of masonry piers shall not exceed ten times there least dimension. When structural clay tile or hollow masonry units are used for isolated piers to support beams and girders, the cellular spaces shall be filled solidly with concrete or type M or S mortar, except that unfilled hollow units may be used if their unsupported height is not more than four times their least dimension. Where hollow masonry units are solidly filled with concrete or type M, S or N mortar the allowable compressive stress shall be permitted to be increased as provided in table R606.4
__________________
Ted Menelly
"Castle"
Home Inspection Services
Reply With Quote
  #4 (permalink)  
Old 07-12-2008, 02:08 PM
wayne soper's Avatar
wayne soper wayne soper is offline
Member
 
Join Date: Mar 2007
Location: Connecticut
Posts: 725
Re: Block piers
Thanks guys, These are not filled
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
box cut into block wall william siegel Electrical Systems: Home Inspection and Commercial Inspection 1 04-28-2008 07:53 PM
Piers David Wood Structural Components: Home Inspection and Commercial Inspection 2 04-04-2008 05:17 PM
New Kid on the block Gordon Douglass Introductions By New Members 1 08-10-2007 04:46 AM
Block Pier Construction Greg Jenkins Sub-Structure: Home Inspection and Commercial Inspection 15 08-01-2007 10:36 PM
Concrete block wayne soper Sub-Structure: Home Inspection and Commercial Inspection 17 04-15-2007 10:31 AM


All times are GMT -7. The time now is 03:35 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger