home inspection

home inspection

home inspector

roof inspection

chimney inspector

Welcome to the InspectionNews Network of Inspection Information

The InspectionNews Information Network has been developed to aid prospective, new and established home inspectors in their quest to find home inspection information and answers to business and technical questions.

The Message Board alone contains over 5,100 registered members who have contributed over 135,579 posts of information. InspectionNews is the largest independent inspection resource of it's kind.

Please register on the message board so you can view the photos and take full advantage of all the message board has to offer.

There are many testimonials from inspectors about why they registered and use InspectionNews everyday.

Links on the site will take you to the industries leading suppliers of products and services covering every aspect of the home and commercial inspection business. You will also find links to other sites containing inspection related and technical information.

Please ENTER here

InspectionNews - Home Inspection
Aluminum wiring with AFCI breakers
Inspected this house today and the seller has had the sub panel (15 and 20 amp circuits) replaced and the new panel now has every circuit on AFCI breakers. House is wired with aluminum wire. Will this panel be protecting all aluminum circuits throughout the house properly? I have never seen this before. Also, some of the older receptacles were not CO/ALR and the aluminum wires have been pigtailed with copper using lavender wire connectors. I now these connectors are not quite safe and other type of connectors are recommended. What would be the best way to report on this? Thank You
Hello to all
Just wanted to say hello to everyone and I hope to learn new ideas and views.
How much lean is acceptable on a Condenser ? See the photos
How much lean is acceptable on a Condenser ? (See the photos). Iwrote both of these up. Both generally appeared to be more than 15 degrees out of level and or close to a problem. What do you guys think ?
a couple of questions from the new home inspector
how do you fix water hammer? is it just in the venting? and the second question, do you have to have a gas shut off in the house?? thanks for any input.
Vent termination
Any thoughts on this furnace vent termination. IRC states 12 inches above the door with exhuast directed away from the building. This was a large condo complex and I don't have my UBC book. The furnace is 85,000 btu high efficiency. Thanks Mat
FPE and Zinsco Panels
Hi guys, I read some of the threads about Zinsco and FPE panels and I am just looking for some general comments which some of you use or don't use. I would appreciate your comments so I can add some to my canned comments. I figured this would be easier than searching all the old threads and create some new discussion about these manufacturers. Bob
Furnace Flue Height Adjacent Fireplace Flue?
Hello to all, Shouldn't the furance flue on left be higher than the fireplace flue?
Reinspection of a deck
This is a picture of a reinspection on a deck. All I wanted them to do was to add some joist hangers. Well they did not add the hangers but they did add a few nails!
OSB on top of cedar shake roof
I have a home being rehabbed. After peeling back 3 layers of asphalt composition shingles, the original roof is cedar shake. Rafters are 24" on center (real 2x6 rough cut - old 1920's home). There are firring strips that were installed onto the cedar shake to provide a level surface to install the comp shingles. I am looking at two scenarios: (a) leave the cedar shake installed with firring strips and install 5/8" OSB on top of this, then install new 30-year architectural shingle roof or (b) complete tear-off down to the rafters and install 3/4" Plywood for support and install new roof. The only concern I have with option "a" is using long enough nails to properly secure OSB sheathing to rafters and dealing with valleys (uneven surface after sheathing put on top of shake. I am thinking rolled paper thickness can compensate for this. All thoughts appreciated.
fireblocking at laundry chute
1969 home yesterday, I wrote up a laundry chute from the 2nd floor to the basement (12' from top of chute to bottom, ~20' from top of chute to basement floor) as a violation of required fire blocking. The laundry chute was actually a metal 4x16 between stud heating duct open at the wall on top and through the bottom to the basement and had a hinged plywood door at the top that swung out into the room. I know that fireblocking is required every 10 feet, but is this being too picky? Would the duct be considered fireblocking within the wall itself, even if it is in contact with wood?
RSS integration by RSSinclude


Please ENTER here
fireplace inspector electrical inspector

inspection

truss inspection

plumbing inspection

plumbing inspection

New York Home Inspection
Los Angeles Home Inspection
Chicago Home Inspection
Houston Home Inspection
Philadelphia Home Inspection
Phoenix Home Inspection
San Antonio Home Inspection
San Diego Home Inspection
Dallas Home Inspection
San Jose Home Inspection
Detroit Home Inspection
Indianapolis Home Inspection
Jacksonville Home Inspection
San Francisco Home Inspection
Columbus Home Inspection
Austin Home Inspection
Memphis Home Inspection
Baltimore Home Inspection
Fort Worth Home Inspection
Charlotte Home Inspection
El Paso Home Inspection
Milwaukee Home Inspection
Seattle Home Inspection
Boston Home Inspection
Denver Home Inspection
Louisville-Jefferson County Home Inspection
Washington Home Inspection
Nashville-Davidson Home Inspection
Las Vegas Home Inspection
Portland Home Inspection
Oklahoma City Home Inspection
Tucson Home Inspection
Albuquerque Home Inspection
Long Beach Home Inspection
Atlanta Home Inspection
Fresno Home Inspection
Sacramento Home Inspection

New Orleans Home Inspection
Cleveland Home Inspection
Kansas City Home Inspection
Mesa Home Inspection
Virginia Beach Home Inspection
Omaha Home Inspection
Oakland Home Inspection
Miami Home Inspection
Tulsa Home Inspection
Honolulu Home Inspection
Minneapolis Home Inspection
Colorado Springs Home Inspection
Arlington Home Inspection